Plain English · From our engineers
Heat Pump & Geothermal Glossary
This glossary from NP Environmental defines the terms Central New York homeowners meet in a heat pump or geothermal proposal: how systems are sized (Manual J, design temperature, Btu/h), how efficiency is measured (COP, HSPF2, SEER2), the equipment (ground loop, desuperheater, ERV) and the NYS Clean Heat program.
4.9 from 138 Google reviews Mitsubishi Electric ELITE Diamond Contractor NYS Clean Heat participating contractor
- Heat pump
- A machine that moves heat instead of making it by burning fuel. In winter it carries heat from outside (the air or the ground) into the house; in summer it reverses and carries heat out. Because moving heat takes less energy than making it, a heat pump delivers more heat than the electricity it uses. More on heat pump
- Geothermal heat pump (ground-source heat pump)
- A heat pump that exchanges heat with the ground through a buried loop of pipe. The ground stays at a steady, mild temperature all year, so the system runs at 300–500% seasonal efficiency. The indoor unit sits inside the house, out of the weather. More on geothermal heat pump
- Cold-climate air-source heat pump
- An air-source heat pump built to keep delivering heat in deep cold. The cold-climate Mitsubishi Electric systems NP Environmental installs run at 200–300% efficiency. Mitsubishi Hyper-Heat H2i models are rated to deliver 100% of their heating capacity down to 5°F, which suits Central New York winters when the system is sized correctly. More on cold-climate air-source heat pump
- Ductless mini-split
- An air-source heat pump with an outdoor unit connected by refrigerant lines to one or more wall, floor or ceiling units inside. It heats and cools rooms directly, so it needs no ductwork. It suits homes heated by baseboard, boilers or stoves. More on ductless mini-split
- Ground loop
- The buried pipe a geothermal system uses to exchange heat with the earth. It is laid in horizontal trenches where there is land, or in vertical bores where space is tight. A properly installed loop is rated for 50+ years (IGSHPA). More on ground loop
- Manual J heat-loss calculation
- The industry method for working out how much heat a house loses on the coldest design day through its walls, windows, roof, floors and air leaks. NP Environmental sizes every system from a full Manual J calculation at Central New York design temperatures, never from the old furnace tag or the square footage. More on manual j heat-loss calculation
- Design temperature
- The outdoor temperature a heating system is engineered to handle on a normal cold winter day for the location. Sizing to the local design temperature, not to an average day, is what keeps a heat pump comfortable in January.
- Building heating load
- The amount of heat a house needs on the design day, measured in British thermal units per hour (Btu/h). It comes from the Manual J calculation and decides the size of the heat pump. The NYS Clean Heat program sets sizing rules against this load.
- British thermal unit per hour (Btu/h)
- The unit used to rate heating and cooling capacity in the United States. One Btu is roughly the heat needed to warm one pound of water by one degree Fahrenheit. Heat pump capacity and building heating load are both stated in Btu/h.
- Coefficient of performance (COP)
- Heat delivered divided by the electricity used, at a given moment. A COP of 3 means three units of heat for every one unit of electricity, or 300% efficiency. COP changes with outdoor or ground temperature, so seasonal figures matter more than a single reading. More on coefficient of performance
- HSPF2 and SEER2
- The US Department of Energy test ratings for air-source heat pumps. Heating seasonal performance factor (HSPF2) rates heating efficiency over a season; seasonal energy efficiency ratio (SEER2) rates cooling efficiency. Higher is better for both. The “2” marks the updated 2023 test procedure.
- Desuperheater
- A small heat exchanger on a geothermal heat pump that takes some of the heat from the compressor and uses it to preheat your domestic hot water. It works hardest when the system is cooling in summer and helps in winter too. A separate tank still finishes the heating. More on desuperheater
- Hydronic heat pump (water-to-water)
- A heat pump that heats water instead of air, for radiant floors, panel radiators or a buffer tank. A geothermal hydronic system draws that heat from the ground loop; an air-to-water system such as Mitsubishi Ecodan draws it from the outdoor air. More on hydronic heat pump
- Radiant floor heating
- Warm water circulating through tubing in or under the floor, so the floor itself heats the room. It runs at low water temperatures, which is exactly where heat pumps work most efficiently. More on radiant floor heating
- Variable refrigerant flow (VRF)
- A larger air-source heat pump system in which one outdoor unit serves many indoor units and varies the refrigerant sent to each. It suits bigger homes and commercial buildings that need many zones. More on variable refrigerant flow
- Dual fuel system
- A heat pump paired with an existing fossil-fuel backup, with controls that decide which one runs. NP Environmental installs the heat pump and controls; we do not repair or service gas or oil furnaces and boilers. More on dual fuel system
- Zoning
- Splitting a home into areas that each have their own thermostat, so you heat or cool only the rooms in use. Ductless heads are zoned by design; ducted systems use dampers and a zone control panel. More on zoning
- Energy recovery ventilator (ERV)
- A ventilation unit that brings in fresh outdoor air and exhausts stale indoor air, passing heat and some moisture between the two streams so little energy is lost. It suits tight, well-sealed homes. More on energy recovery ventilator
- MERV rating
- Minimum efficiency reporting value: a 1–16 scale for how well an air filter catches particles. Higher numbers catch finer particles but can restrict airflow, so the filter has to suit the system’s fan and ductwork. More on merv rating
- Commissioning
- The checks after installation that prove the system runs as designed: refrigerant charge or loop flow, airflow or water flow, temperatures and controls. NP Environmental commissions every system against its documented design before handover. More on commissioning
- NYS Clean Heat
- New York State’s heat pump incentive program, delivered through your electric utility (NYSEG, RG&E or National Grid in Central New York). The participating contractor files the rebate reservation; homeowners cannot apply directly. We confirm your exact figure at the free home assessment. More on NYS Clean Heat rebates
- Decommissioning
- Permanently removing or disabling the old fossil-fuel heating system when a heat pump replaces it. Under NYS Clean Heat this applies to air-source systems, where a decommissioned system qualifies for a different incentive category than one kept as backup. More on decommissioning
- NYSERDA
- The New York State Energy Research and Development Authority, the state agency that runs energy-efficiency and clean-heating programs alongside the utilities’ NYS Clean Heat rebates. More on rebates and financing
- IGSHPA
- The International Ground Source Heat Pump Association, the body behind geothermal design and installation standards, including the 50+ year service life of a ground loop. NP Environmental builds to IGSHPA standards. More on our affiliations
- NP Shield™ 10+2
- NP Environmental’s extended labor warranty: up to 12 years of labor coverage on eligible work, so a covered repair does not come with a labor bill. More on NP Shield™
Missing a term? Ask us on (315) 841-8730 or read the heat pump FAQ.
Questions about your own proposal?
Book a free estimate and energy audit. You’ll get the heat-loss calculation, your system options, and the full New York rebate stack — in writing.