Skip to content
NP Environmental — Heat Pump Heating & Cooling

Learning Center · December 25, 2023

What Exactly Is Refrigerant?

Refrigerant is the working fluid inside a heat pump: a compound that boils and condenses at useful temperatures and pressures, absorbing heat as it boils and releasing it as it condenses. Cycling through a sealed copper loop, it lets an air-source heat pump deliver 200–300% seasonal efficiency and a geothermal system 300–500%.

By the NP Environmental Team, Waterville, NY · Published December 25, 2023

Refrigerant is the working fluid inside every heat pump, and it is the reason the system can move heat rather than make it. Most homeowners never see it and rarely think about it — until a technician mentions a leak. Here is what it is, how it works, and why the industry is changing what goes in the pipes.

What is refrigerant?

Refrigerant is a chemical compound chosen because it boils and condenses at useful temperatures and pressures. That sounds mundane, but it is the whole trick: when a liquid boils it absorbs a great deal of heat, and when a vapor condenses it releases that heat again. A heat pump exploits that cycle continuously, in a sealed loop of copper, to carry heat from one place to another.

Modern residential refrigerants are hydrofluorocarbon blends, engineered to do this job efficiently, safely, and with as little environmental impact as the chemistry allows.

How the refrigeration cycle works

  1. Evaporation: on the low-pressure side of the system, liquid refrigerant passes through a coil and boils, absorbing heat from whatever is around it — the outdoor air in winter, or the air in your rooms in summer.
  2. Compression: the compressor squeezes that vapor, raising its pressure and temperature sharply.
  3. Condensation: the hot, high-pressure vapor flows through the other coil and condenses back to a liquid, releasing its heat — into your home in winter, or outdoors in summer.
  4. Expansion: the liquid passes through a metering device that drops its pressure, and the cycle starts again.

A reversing valve swaps which coil does which job, which is why one heat pump both heats and cools. Because the energy goes into moving heat rather than creating it, an air-source heat pump delivers 200–300% seasonal efficiency and a geothermal system 300–500%. More on how our heat pump systems put that to work.

The types of refrigerant

  • R-22 (often called Freon): the standard for decades, now phased out of production because of its effect on the ozone layer. Systems still running on it can be serviced, but the refrigerant is scarce and expensive, and a major leak usually means it is time to replace the equipment.
  • R-410A (often called Puron): the refrigerant in most heat pumps installed over the past couple of decades. It does not harm the ozone layer, but it operates at high pressure and has a high global warming potential if it escapes.
  • The next generation: the industry is moving to lower-GWP refrigerants such as R-454B and R-32. New equipment is being designed around them, and the manufacturers we install — Mitsubishi among them — are making that transition now. For a homeowner, the practical differences are small: the equipment looks and works the same, and the environmental footprint of any leaked refrigerant is far lower.

What a refrigerant leak means

A sealed system should never lose charge. If it does, something is wrong: a braze joint, a flare fitting, a corroded coil, a rubbing line. A low charge shows up as longer run times, lukewarm air, ice on the coil, or a system that cannot keep up. Topping it off without finding the leak is not a repair; it is a recurring bill and a slow release of refrigerant into the atmosphere.

This is why we take commissioning seriously. Every air-source system we install gets a nitrogen pressure test to prove the circuit is tight, then a deep evacuation to pull out air and moisture before the refrigerant is released, and the readings are recorded and handed to you. Done right, the charge that goes in on install day is the charge the system runs on for its whole life. Our maintenance visits verify it each year.

Questions about your system?

If your heat pump is on R-22, is struggling to keep up, or you suspect a leak, schedule a service visit or call (315) 841-8730. Weighing a replacement? Book a free home assessment and we will size and design the new system properly.

Straight answers

Questions readers ask

Can I still get my R-22 heat pump serviced?

Yes, a heat pump running on R-22 can still be serviced. R-22 has been phased out of production, so the refrigerant is scarce and expensive. A small repair can still make sense, but a major leak on an R-22 system usually means it is time to replace the equipment with a modern heat pump.

Does a heat pump ever need its refrigerant topped up?

Not if it is working properly. A heat pump is a sealed system and should never lose charge. A low charge means a leak at a braze joint, a flare fitting, a corroded coil or a rubbing line. Topping it off without finding the leak is not a repair; it is a recurring bill, so the leak gets found and fixed.

Do heat pumps using R-454B or R-32 refrigerant work differently for homeowners?

For homeowners the practical differences are small. Heat pumps designed around R-454B or R-32 look and work the same as earlier equipment. These refrigerants have a lower global warming potential (GWP), so any refrigerant that leaks has a far smaller environmental footprint. Manufacturers we install, Mitsubishi among them, are making the transition now.

Talk to the engineers behind the articles

Book a free estimate and energy audit. You’ll get the heat-loss calculation, your system options, and the full New York rebate stack — in writing.

Call (315) 841-8730 Book Free Assessment